<ErrorNumber>43021</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: The chemical filter usage sensor is corrupt or the chemical filter was changed and the output device was not reset
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The chemical filter usage sensor has become corrupt and is not providing valid
usage information or the chemical filter was replaced and the output device was
not reset.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
If the chemical filter has just been replaced, you must reset the  output device
so that it recognizes the new filter.  If the chemical filter has not been replaced
recently then the filter usage sensor has become corrupt.  You must replace the
chemical filter to continue imaging.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Cause 1: The chemical filter has been replaced but the output device has not been rebooted
or the machine has been rebooted without the chemical filter.
Solution:  Replace chemical filter and then turn the output device on and off (simple software
reset command may not work!).
</Cause>
<Cause>
Cause 2:  The chemical filter has been installed incorrectly.
Solution: Make sure that the chemical filter has been installed with the rubber gasket down so it
contacts the bottom of the pot. There should be a metal cylindrical guide that first sits in the
bottom of the pot to center the chemical filter.  Try rotating the chemical filter by 90 degrees
to establish new contact points with the chemical filter I-button.  Then a spacer rests on
the chemical filter, and the particulate filter sits on top of the spacer.  It should sit
square to the pot and the foam gasket should protrude about 1/4" above the rim. Turn the output
device off / on to continue.
</Cause>
<Cause>
Cause 3:  The chemical filter usage sensor is corrupt
Solution: If the chemical filter has not been replaced recently then the filter usage sensor has become corrupt.  You must replace the chemical filter to continue imaging. Replace the chemical filter then reset the output device to continue.
</Cause>
<LastModified>
07-Jul-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:36 2008 PST
</Updated>
<Links>
</Links>
</Error>